翻訳と辞書
Words near each other
・ Variable Rate Application
・ Variable rate debt obligation
・ Variable rate feeder
・ Variable Rate Technology
・ Variable refrigerant flow
・ Variable reluctance sensor
・ Variable renewable energy
・ Variable retention
・ Variable rules analysis
・ Variable seedeater
・ Variable shadowing
・ Variable shunt reactor
・ Variable skink
・ Variable soft coral
・ Variable Specific Impulse Magnetoplasma Rocket
Variable speed fire pump controller
・ Variable speed of light
・ Variable speed wind turbine
・ Variable splitting
・ Variable Star
・ Variable star
・ Variable star designation
・ Variable structure control
・ Variable structure system
・ Variable sunbird
・ Variable surface glycoprotein
・ Variable symbol
・ Variable translation control
・ Variable triplefin
・ Variable type


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Variable speed fire pump controller : ウィキペディア英語版
Variable speed fire pump controller

A Variable Speed (VFD) Fire Pump Controller is a fire pump controller that is able to vary the speed of the motor depending on the demand of the fire pump, resulting in the ability to hold a constant discharge pressure. It differs from other industrial variable speed control devices because it is now considered a life safety device, and so must adhere to the more rigid standards set forth by (NFPA-20. )
==History==
Variable Speed Fire Pump Controllers were invented and released with a UL Listing for fire pump service in 2003 by (Master Control Systems, Inc. )〔Underwriters Laboratories. 14 January 2010 ("Pump Controllers, Fire ), 1-2.〕〔Master Control Systems, Inc. 6 January 2010 ("Variable Speed Fire Pump Controllers" )〕 Paragraph 10.5.5 in the 2003 edition of NFPA-20 recognized Variable Speed as an accepted method for operating the fire pump. Then in the NFPA-20 2007 edition, section 10.10 was added to clarify and enhance the previous standards. In addition to reading these standards, a detailed summary of them by James S. Nasby of Columbia Engineering can be found (on slides 7-11. ) In 2008 (Master Control Systems, Inc. ) became the first company to provide FM Approval for the controller. A full list of companies with FM Approval may be found (here. ) 〔Factory Mutual. 14 January 2010 ("Approval Guide" )〕 Variable Speed Fire Pump Controllers are now accepted by NFPA-20, Underwriters Laboratories (UL), and most recently Factory Mutual (FM) for fire pump applications.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)